Senin, 12 Oktober 2009 di 22.58 | 0 komentar  




NEIGHBOUR ANALYSIS



Analysis of existing neighbours

Following needs to be checked of the existing neighbor definitions:

1. Non-mutual neighbors

2. Neighbors with same BCCH in source and target cell





Finding non-mutual neighbours



All neighbors in Taliya radio network shall have mutual neighbor relations. Non-mutual neighbors are found by looking into each of the BSC database dumps. A macro have been created in order to facilitate the cross check of the neighbor definitions. The macro by the name ’BSC extractor’ can be found on the server.

Figure 1:BSC Extractor for BSC Database checks



It is also possible to check the neighbor definitions by excel. One example of how to find non-mutual neighbors in Excel is described below:

UExample, One-way neighbors

Assume there are three cells ABC1, ABC2 and ABC3. ABC1 and ABC2 have a mutual neighbor relation and ABC1 and ABC3 have a non-mutual neighbor relation. To find non- mutual neighbors it is recommended to concatenate the Cell IDs in two different columns forwards and backwards and finally use “vlookup” formula to find out if the each single item in column 1 (named concat1) can be found in column 2 (named concat2) as shown below:

Table 1: Table showing how to find one-way neighbours



Since ABC1 and ABC2 have a mutual neighbor relation the “Vlookup” column returns the correct text strings. The neighbor relation ABC1 to ABC3 is one-way and is found by

“vlookup” by returning “#N/A”.



Correct non-mutual neighbours

If non-mutual neighbors are found the neighbor definition should be deleted or defined as mutual.



Finding neighbours with same BCCH in source and target cell



In order for the MS to distinguish between the serving cell and its neighbors and to minimize handover problems, source cell and target cell in a neighbor relation must have different BCCH frequencies.

To find neighbor relations with same BCCH frequencies for both source and target cell it is recommended to use the BSC extractor in order to generate into excel the neighbors with the BCCH for the source and target cell. Then simply use the formula “Exact” to find out if the BCCH frequencies for source cell and target cells are the same as shown below:

Table 2: Table showing how to find source and target cells with same BCCH frequencies



As shown in XTable 2X ABC1 and ABC3 have same BCCH and is found by the “exact” formula by returning the value “TRUE” in column “Exact”.



Delete or correct neighbours with same BCCH in source and target cell Neighbors with same BCCH frequency for source and target cell must be deleted. If the neighbor is required the BCCH frequency of either the source cell or target cell must be changed. This is required to be checked after each new frequency plan and neighbor definition.



Add Missing Neighbours

To make it possible to do handovers, neighbor definitions are required. If there are any missing neighbors in the network, the best servers cannot be allocated. As a result the customer perceived coverage and quality will be worse than the actual situation and cause an increased Call Drop Rate. Therefore it is essential that there are no missing neighbors in the network.

To find all missing neighbors both drive test logfiles and existing neighbors displayed in Asset must been analyzed. Drive tests should include both a MS in scanning mode (BCCH frequencies) and a MS in dedicated mode. If the MS in scanning mode found a cell with higher signal strength than the cell that is allocated by the MS in dedicated mode and a handover is not made to the best scanned cell, the neighbor is probably missing. Below the dedicated mode and the strongest scanned frequency are compared. As long as the MS in dedicated mode is using the same frequency as the strongest scanned channel no neighbors are missing:

Figure 2: TEMS plot showing the serving cell frequency of the MS in dedicated mode and the strongest scanned channel. In this example both frequencies are the same and no missing neighbour is detected.



To facilitate finding missing neighbors it is recommended to include all neighbors in the TEMS cell file. TEMS Investigation will highlight all neighbors with a different color as shown below and it will be clear if a neighbor is missing:







Figure 3: TEMS Investigation with a cell file with neighbours. Neighbouring cells are shown with a different color



Diposting oleh Pathloss50 Label:
Firstly this H+A+C+k works on the new firmwares [os 9.3 FP2 phones]. However, it should work with all firmwares now h+a+c+k+a+b+l+e. All other similar devices are already present on the forum but the point of my message is to offer the fastest available ******** for the symbia OS. Just download the attachment only for binpda h+a+c+k+i+n+g kit and your phone is ready to be c+r+a+c+k+e+d in 2 minutes. Even all installserver.exe for all phones are included in this single file. So you do not move the files here and there with xplore. No more errors in the certificate, no more license expired Just install any file, even if the signature or certificate expired ... During installation choose the server installation according to your phone .. As seen in sceenshot or to choose 3 files.
* Binpda Security Manager
* Installserver.exe [as telephone]
* Capsoff driver [as telephone]




SYMBIAN DEVICE LIST
Symbian 9.1 [Pre-FP1 devices]
-------------------
Nokia N77
Nokia E61i
Nokia E65
Nokia N93i
Nokia N91 8GB
Nokia E62
Nokia E50
Nokia 5500
Nokia N93
Nokia N73
Nokia N80
Nokia N71
Nokia N92
Nokia E70
Nokia E60
Nokia E61
Nokia 3250

Symbian 9.2 [FP1 devices]
---------------
Nokia 6124 classic
Nokia N82
Nokia N95-3 NAM
Nokia E51
Nokia N95 8GB
Nokia N81
Nokia N81 8GB
Nokia 6121 classic
Nokia 6120 classic
Nokia 5700 XpressMusic
Nokia 6110 Navigator
Nokia E90 Communicator
Nokia N76
Nokia 6290
Nokia N95

Symbian 9.3 [FP2 devices]
-------------------
Nokia N96
Nokia N85
Nokia N79
Nokia 6220c
Nokia E66
Nokia E71

here your tools
Diposting oleh Pathloss50 Label:
Selasa, 29 September 2009 di 00.18 | 0 komentar  
Finnally My Pathloss 5.0 full Available and No more Bug.....


Tutorial How to used Pathloss 5.0 will create soon ^_^
Diposting oleh Pathloss50 Label:

Pathloss 5 - Revision History

Pathloss 5.0 Update : 13 Jan 2010
Pathloss 5.0 Update 23 Dec 2009 :

Pathloss 5.0 Update 17 Dec 2009 :

Part 1 Part 2

PL5 Update 2 Dec 09

part1 part2 part3

Pathloss version 5 - Maintenance update - Build date December 02, 2009

Check the build date of your current installation. Click the Help - About Pathloss 5.0 menu item.

If the build date is May 7, 2009 or newer, then use the link below to download the December 02, 2009 maintenance update

This is an InstallShield installation program. The Pathloss program must be closed to run this update

If the build date of the current installation is earlier than May 7, 2009 then the update must be carried out as a new installation as described below.

Pathloss version 5 - Maintenance update using a new installation

Your existing installation must be first be uninitialized and then the program must be removed.

The following steps detail the procedure.

Start the Pathloss program

Click Configure - Pathloss program - Uninitialize program

If you were able to initialize the program on line, then select this option and click the Uninitialize Program button. You will be prompted to proceed with the uninitialization. This step will automatically update the licensing database for the next installation.

If you were not able to initialize the program on line due to the program internet access restrictions, then select the EMail option and click the Uninitialize Program button.

You will first be prompted to proceed with the uninitialization. Once the program has been uninitialized, the dialog on the left will appear. Click the "Copy serial number and uninitialization code" button. This step copies these two item to the clip board.

Create a new Email to cte@pathloss.com and paste (Ctrl V) the serial number and uninstallation code into the EMail body.

When we receive the EMail, the licensing database will be updated for the next installation.

Note that the uninitialization procedure (on line and EMail) creates the file "pluninst.txt" in the tmp_file folder. This file contains the serial number and uninstallation code. This also can be Emailed to update the installation status

Once the program has been uninitialized, remove the Pathloss program using the Control Panel operation "Add or Remove Programs" to remove the Pathloss program.

Finally download and install the latest program build using the procedure supplied with your serial number notification

Important note to VISTA users

It will be necessary to manually delete all files in the directory

C:\Users\\AppData\Local\VirtualStore\Program Files\Pathloss 5\geo_data

before installing the complete program.


Pathloss version 5 - Maintenance update - Build date November 25, 2009

Check the build date of your current installation. Click the Help - About Pathloss 5.0 menu item.

If the build date is May 7, 2009 or newer, then use the link below to download the November 25, 2009 maintenance update.

Pathloss Update : Part1 Part2 Part3

This is an InstallShield installation program. The Pathloss program must be closed to run this update

If the build date of the current installation is earlier than May 7, 2009 then the update must be carried out as a new installation as described below.

Pathloss version 5 - Maintenance update using a new installation

Your existing installation must be first be uninitialized and then the program must be removed.

The following steps detail the procedure.

Start the Pathloss program

Click Configure - Pathloss program - Uninitialize program

If you were able to initialize the program on line, then select this option and click the Uninitialize Program button. You will be prompted to proceed with the uninitialization. This step will automatically update the licensing database for the next installation.

If you were not able to initialize the program on line due to the program internet access restrictions, then select the EMail option and click the Uninitialize Program button.

You will first be prompted to proceed with the uninitialization. Once the program has been uninitialized, the dialog on the left will appear. Click the "Copy serial number and uninitialization code" button. This step copies these two item to the clip board.

Create a new Email to cte@pathloss.com and paste (Ctrl V) the serial number and uninstallation code into the EMail body.

When we receive the EMail, the licensing database will be updated for the next installation.

Note that the uninitialization procedure (on line and EMail) creates the file "pluninst.txt" in the tmp_file folder. This file contains the serial number and uninstallation code. This also can be Emailed to update the installation status

Once the program has been uninitialized, remove the Pathloss program using the Control Panel operation "Add or Remove Programs" to remove the Pathloss program.

Finally download and install the latest program build using the procedure supplied with your serial number notification

Important note to VISTA users

It will be necessary to manually delete all files in the directory

C:\Users\\AppData\Local\VirtualStore\Program Files\Pathloss 5\geo_data

before installing the complete program.


-------------------------------------------------------------------------------------

Pathloss version 5 - Maintenance update - Build date November 20, 2009

Check the build date of your current installation. Click the Help - About Pathloss 5.0 menu item.

If the build date is May 7, 2009 or newer, then use the link below to download the November 10, 2009 maintenance update.

Pathloss 5 update

Antenna Radian Setup

This is an InstallShield installation program. The Pathloss program must be closed to run this update

If the build date of the current installation is earlier than May 7, 2009 then the update must be carried out as a new installation as described below.

---------------------------------------------------------------------------------------------


Pathloss version 5 - Maintenance update using a new installation

Your existing installation must be first be uninitialized and then the program must be removed.

The following steps detail the procedure.

Start the Pathloss program

Click Configure - Pathloss program - Uninitialize program

If you were able to initialize the program on line, then select this option and click the Uninitialize Program button. You will be prompted to proceed with the uninitialization. This step will automatically update the licensing database for the next installation.

If you were not able to initialize the program on line due to the program internet access restrictions, then select the EMail option and click the Uninitialize Program button.

You will first be prompted to proceed with the uninitialization. Once the program has been uninitialized, the dialog on the left will appear. Click the "Copy serial number and uninitialization code" button. This step copies these two item to the clip board.

Create a new Email to cte@pathloss.com and paste (Ctrl V) the serial number and uninstallation code into the EMail body.

When we receive the EMail, the licensing database will be updated for the next installation.

Note that the uninitialization procedure (on line and EMail) creates the file "pluninst.txt" in the tmp_file folder. This file contains the serial number and uninstallation code. This also can be Emailed to update the installation status

Once the program has been uninitialized, remove the Pathloss program using the Control Panel operation "Add or Remove Programs" to remove the Pathloss program.

Finally download and install the latest program build using the procedure supplied with your serial number notification

Important note to VISTA users

It will be necessary to manually delete all files in the directory

C:\Users\\AppData\Local\VirtualStore\Program Files\Pathloss 5\geo_data

before installing the complete program.



Pathloss 5 - Revision Date March 10, 2009

Radio lookup tables can load version 4 microwave (mrd) and VHF-UHF (vrd) lookup files.

CSV Link reports have been added. They can be found under the Operations menu in the network display. The report can be customized by clicking the 'Edit' button and selecting CSV Link report from the dropdown list in the report settings window. (More report settings are available in the tree list on the left.)


Pathloss 5 - Revision Date February 24, 2009

Radio lookup tables
This has been added as an option to using the radio code index. If a code exists in the table, the, lookup table functions the same as the radio code index.

Loading pl4 files which contained Fresnel references became corrupted when saved as PL5 files. Interference calculations for base stations without associated links has been implemented.


Pathloss 5 - Revision Date February 12, 2009

Base station sector frequency assignments
The TX channel table and frequency plan files are now used for frequency assignments.

Point to multipoint design
The base antenna height is not considered in the rejection criteria.

Google Earth kml export
General improvements to the overall display.

Local and area studies are now exported as separate entities for each signal level.

Metric conversion problems - (feet and miles only).

Error in transmission line unit loss in ptmp link design corrected.

Error in tower heights corrected.

Diposting oleh Pathloss50 Label: ,